944 CHAPTER 76: RMON CONFIGURATION
n
Two entries with the same configuration cannot be created. If the parameters
of a newly created entry are identical to the corresponding parameters of an
existing entry, the system considers their configurations the same and the
creation fails. Refer to Table 75 for the parameters to be compared for different
entries.
The system limits the total number of all types of entries. When the total
number of an entry reaches the maximum number of entries that can be
created, the creation fails.
When you create an entry in the history table, if the specified buckets number
argument exceeds the history table size supported by the device, the entry will
be created. However, the validated value of the buckets number argument
corresponding with the entry is the history table size supported by the device.
Displaying and
Maintaining RMON
Create an entry in the private
alarm table
rmon prialarm entry-number
prialarm-formula prialarm-des
sampling-interval { absolute |
changeratio | delta }
rising-threshold threshold-value1
event-entry1 falling-threshold
threshold-value2 event-entry2
entrytype { forever | cycle
cycle-period } [ owner text ]
Optional
To do… Use the command… Remarks
Table 75 Restrictions on the configuration of RMON
Entry Parameters to be compared
Event Event description (description string), event type (log, trap,
logtrap or none) and community name (trap-community or
log-trapcommunity)
History Sampling interval (interval sampling-interval)
Statistics Only one statistics entry can be created on an interface.
Alarm Alarm variable (alarm-variable), sampling interval (sampling-interval),
sampling type (absolute or delta), rising threshold
(threshold-value1) and falling threshold (threshold-value2)
Pri-alarm Alarm variable formula (alarm-variable), sampling interval
(sampling-interval), sampling type (absolute, changeratio or
delta), rising threshold (threshold-value1) and falling threshold
(threshold-value2)
To do… Use the command… Remarks
Display RMON statistics display rmon statistics
[ interface-type interface-number ]
Available in any
view
Display RMON history information
and the latest history sampling
information
display rmon history [ interface-type
interface-number ]
Available in any
view
Display RMON alarm configuration
information
display rmon alarm [ entry-number ] Available in any
view
Display RMON prialarm
configuration information
display rmon prialarm
[ entry-number ]
Available in any
view
Display RMON events
configuration information
display rmon event [ entry-number ] Available in any
view