68 CHAPTER 5: LOGGING IN THROUGH WEB-BASED NETWORK MANAGEMENT SYSTEM
# Configure the user name to be admin.
[SW4800G] local-user admin 
# Set the user level to level 3.
[SW4800G-luser-admin] service-type telnet level 3 
# Set the password to admin.
[SW4800G-luser-admin] password simple admin 
Step 3: Establish an HTTP connection between your PC and the switch, as shown 
in the following figure.
Figure 19   Establish an HTTP connection between your PC and the switch
 
Step 4: Log in to the switch through IE. Launch IE on the Web-based network 
management terminal (your PC) and enter the IP address of the management 
VLAN interface of the switch (here it is http://10.153.17.82). (Make sure the route 
between the Web-based network management terminal and the switch is 
available.)
Step 5: When the login interface (shown in Figure 20) appears, enter the user 
name and the password configured in step 2 and click <Login> to bring up the 
main page of the Web-based network management system.
Figure 20   The login page of the Web-based network management system
 
Web Server 
Shutdown/Startup
You can shut down or start up the Web server.
SwitchPC
HTTP 
Connection
To do…  Use the command…  Remarks 
Enter system view  system-view - 
Shut down the Web server  undo ip http enable Required
Execute this command in system view.
The Web server is started by default.