1062 CHAPTER 86: NQA CONFIGURATION
Configuring trap delivery
Follow these steps to configure trap delivery:
Configuring Optional
Parameters Common
to an NQA Test Group
Optional parameters common to an NQA test group are valid only for tests in this
test group.
Unless otherwise specified, the following parameters are applicable to all test
types and they can be configured according to the actual conditions.
Follow these steps to configure optional parameters common to an NQA test
group:
To do… Use the command… Remarks
Enter system view system-view -
Enter NQA test group view nqa entry admin-name
operation-tag
-
Enter test type view of the test
group
type { dhcp | dlsw | ftp |
http | icmp-echo | snmp |
tcp | udp-echo | udp-jitter }
-
Configure to send traps to
network management server
under specified conditions
reaction trap
{ probe-failure
consecutive-probe-failures |
test-complete | test-failure
cumulate-probe-failures }
Optional
No traps are sent to the
network management server
by default.
To do… Use the command… Remarks
Enter system view system-view -
Enter NQA test group view nqa entry admin-name
operation-tag
-
Enter test type view of a
test group
type { dhcp | dlsw | ftp |
http | icmp-echo | snmp |
tcp | udp-echo |
udp-jitter }
-
Configure the descriptive
string for a test group
description string Optional
By default, no descriptive string is
available for a test group.
Configure the interval
between two consecutive
tests for a test group
frequency interval Optional
By default, the interval between two
consecutive tests for a test group is
0 milliseconds, that is, only one test
is performed.
If the last test is not completed
when the interval specified by the
frequency command is reached, a
new test is not started.
Configure the number of
probes in a test
probe count times Optional
By default, one probe is performed
in a test.

Table of Contents