EasyManua.ls Logo

3Com Switch 4800G 24-Port - Configuring a Power Alarm Threshold for the PSE; Upgrading PSE Processing Software Online

3Com Switch 4800G 24-Port
1246 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring a Power Alarm Threshold for the PSE 1197
interface from critical to a lower level, the PDs connecting to other PoE interfaces
will have an opportunity of being powered.
Configuration prerequisites
Enable PoE for PoE interfaces.
Configuration procedure
Follow these steps to configure PD power management:
Configuring a Power
Alarm Threshold for
the PSE
When the current power utilization of the PSE is above or below the alarm
threshold for the first time, the system will send a Trap message.
Upgrading PSE
Processing Software
Online
You can upgrade the PSE processing software online in either of the following two
modes:
refresh mode
This mode enables you to update the PSE processing software without deleting it.
Normally, you can upgrade the PSE processing software in the refresh mode
through the command line.
full mode
This mode deletes the PSE processing software and reloads it. When the PSE
processing software is damaged (in this case, you can execute none of PoE
commands successfully), you can upgrade the PSE software processing software in
full mode to restore the PSE function.
To do… Use the command… Remarks
Enter system view system-view -
Configure
the power
priority for a
PoE interface
Configure the power priority
for the PoE interface in PoE
interface view
interface
interface-type
interface-number
Use either command.
By default, the power
priority of a PoE
interface is low. poe priority { critical |
high | low }
Configure the power priority
for the PoE interface in PoE
configuration file view
poe-profile
profile-name [ index ]
poe priority { critical |
high | low }
Configure a PD power management priority
policy
poe pd-policy
priority
Optional
By default, no PD
power management
priority policy is
configured.
To do… Use the command… Remarks
Enter system view system-view -
Configure a power alarm
threshold for the PSE
poe utilization-threshold
utilization-threshold-value
Optional
80% by default.

Table of Contents