1206 CHAPTER 94: SFLOW CONFIGURATION
Troubleshooting sFlow
Configuration
The Remote sFlow
Collector Cannot Receive
sFlow Packets
Symptom
The remote sFlow collector cannot receive sFlow packets.
Analysis
sFlow is not enabled globally because the sFlow agent or/and the sFlow
collector are not specified.
No port is enabled with sFlow to sample data.
The IP address of the sFlow collector specified on the sFlow agent is different
from that of the remote sFlow collector.
No IP address is configured for the Layer 3 interface on the device, or the IP
address is configured, but the UDP packets with the IP address being the source
cannot reach the sFlow collector.
The physical link between the device and the sFlow collector fails.
Solution
1 Check whether sFlow is correctly configured by displaying sFlow configuration
with the display sflow command.
2 Check whether the correct IP address is configured for the device to communicate
with the sFlow collector.
3 Check whether the physical link between the device and the sFlow collector is
normal.