218 CHAPTER 23: MSTP CONFIGURATION
n
A larger maximum hops setting means a larger size of the MST region. Only the
maximum hops configured on the regional root bridge can restrict the size of the
MST region.
Configuration example
# Set the maximum hops of the MST region to 30.
<Sysname> system-view
[Sysname] stp max-hops 30
Configuring the
Network Diameter of a
Switched Network
Any two stations in a switched network are interconnected through specific paths,
which are composed of a series of devices. Represented by the number of devices
on a path, the network diameter is the path that comprises more devices than any
other among these paths.
Configuration procedure
Follow these steps to configure the network diameter of the switched network:
n
Network diameter is a parameter that indicates network size. A bigger network
diameter represents a larger network size.
Based on the network diameter you configured, MSTP automatically sets an
optimal hello time, forward delay, and max age for the device.
The configured network diameter is effective for the CIST only, and not for
MSTIs.
Configuration example
# Set the network diameter of the switched network to 6.
<Sysname> system-view
[Sysname] stp bridge-diameter 6
Configuring Timers of
MSTP
MSTP involves three timers: forward delay, hello time and max age. You can
configure these three parameters for MSTP to calculate spanning trees.
Configuration procedure
Follow these steps to configure the timers of MSTP:
To do… Use the command… Remarks
Enter system view system-view -
Configure the network diameter of the
switched network
stp bridge-diameter bridge-number Optional
7 by default
To do… Use the command… Remarks
Enter system view system-view -
Configure the forward delay
timer
stp timer forward-delay
centi-seconds
Optional
1,500 centiseconds (15
seconds) by default
Configure the hello time timer stp timer hello centi-seconds Optional
200 centiseconds (2 seconds)
by default