8
Modbus Communication
- 8.4
Address for Modbus
62
40100
FAIL limit
Q
0.1 to 99.9
40116
Sensitivity adjustment,
Default belt speed
10.0 to 60.0
40101
FAIL limit
P
0.1 to 99.9
40117
Sensitivity adjustment,
Default product length
1 to 1000
40102
FAIL limit P
shortage (deoxidant)
0.1 to 99.9
40118
Sensitivity adjustment,
Reset counter
0 to 1
40103
Under limit
0.1 to 99.9
40119
Count mode
0 to 1
40104
Phase I
0.5 to 180.0
40120
FAIL count mode
0 to 7
40105
Phase Q
0.5 to 180.0
40121
Belt stop at FAIL
0 to 1
40106
Phase P
0.5 to 180.0
40122
Distance to stop
1 to1000
40107
Phase tracking
ON/OFF
0 to 1
40123
Delay time of detection
0.00 to 9.99
40108
Phase tracking reset
ON/OFF
0 to 1
40124
Init. phase mode
0 to 2
40109
Calibration, PASS count
0 to 10
40125
Number of init. phase
1 to 10
40110
Calibration, FAIL count
0 to 10
40126
Number of phase adjustment
1 to 10
40111
Calibration error
0 to 1
40127
Rejector error
0 to 1
40112
FAIL 1 ON/OFF
0 to 1
40113
FAIL 2 ON/OFF
0 to 1
40114
FAIL 3 ON/OFF
0 to 1
40115
FAIL 4 ON/OFF
0 to 1
C
CAUTION
The register ignores the decimal point of data and stores data.
Example: If data is between 0.0 and 99.99, a value between 0 and 9999 is inputted and
stored in the register.