AMT/PTD/PBX/0058/4/6/EN Installation and Maintenance Manual - Aastra 5000
Page 436 01/2011 Maintenance
SHEET E-11 STANDARD REPLACEMENT OF AN AXD MAIN CABINET
AVAILABILITY
• No mission capable
OPERATORS (s)
• 1 operator on site
DURATION
• 20 minutes
INGRÉDIENT(S)/CONSOMMABLE(S)
•N/A
Table 18:
OPERATION DETAILS OF THE OPERATION / COMMENTS
• Back up the customer
configuration.
• Precautionary operation to be carried out if there is no existing
copy (which is the case when previous installation operations
have been carried out and the procedures followed).
• Refer to [1]
• In the case of remote operation, contact the remote operator
before starting any operation.
• Power off the iPBX. • Refer to Section 6.4, Stopping the system (AXD, AXL, AXS,
AXS12 and AXS6)Error! No bookmark name given.
• For a system with several cabinets, first power off the main
cabinet, then the expansion cabinet.
Nota : It is advisable to stop the IPS card before powering off the
iPBX.
• Disconnect the cables. • Disconnect the mains cable.
• Disconnect the cables connected to the front panel of the UCV-
D, IUCV-D cards and those on the cabinet's expansion cards and
mark the cables for refitting.
• For a system with several cabinets, disconnect the cable located
at the rear of the cabinet.
• Remove the old cabinet.
• Remove the IUCV-D card. • Pull out the IUCV-D card from its slot using
the 1/4 turn locks (see Figure 4.1 ).
• Retrieve the module.
i-Button.
• Recover, on the IUCV-D card, the i-button module containing the
system's identifier.
• Remove the new IUCV-D
card.
• Pull out the new IUCV-D card from its slot using the 1/4 turn
locks (seeFigure 4.1 ).