Loading...
Recommended annual actions by the user
IDustiness, corrosion and temperature
PHeatsink cleaning
Years from start-up
Component
21181512963
Cooling
RRMain cooling fans
RRCircuit board com-
partment cooling
fans LONGLIFE
Aging
RRControl panel bat-
tery
Functional safety
ISafety function test
See the maintenance information of the safety function.
20 yearsSafety component
expiry (Mission
time,
T
M
)
Maintenance and component replacement intervals are based on the assumption that
the equipment is operated within the specified ratings and ambient conditions. ABB
recommends annual drive inspections to ensure the highest reliability and optimum
performance.
Note: Long term operation near the specified maximum ratings or ambient conditions
may require shorter maintenance intervals for certain components. Consult your local
ABB Service representative for additional maintenance recommendations.