-40…+70 °C (-40 …
+158 °F)
-40 … 70 °C (-40 …
+158 °F)
-15…+55 °C (5…+131 °F).
Derating is necessary if
the temperature is more
than 40 °C (104 °F). Refer
to the derating informa-
tion.
Surrounding air temper-
ature
No frost permitted.
Max. 95%Max. 95%5…95%Relative humidity
No condensation permitted. Maximum permitted relative humidity is 60% in
the presence of corrosive gases.
IEC 60721-3-2:1997IEC 60721-3-1:1997IEC/EN 60721-3-3:2002Contamination
Class 2C2Class 1C2Class 3C2Chemical gases
Class 2S2Class 1S3. (packing must
support this, otherwise
1S2)
Class 3S2. No conductive
dust permitted.
Solid particles
2Pollution degree
60…106 kPa (0.6 … 1.05
atmospheres)
70…106 kPa (0.7 … 1.05
atmospheres)
70…106 kPa (0.7 … 1.05
atmospheres)
Atmospheric pressure
Max. 3.5 mm (0.14 in)
(2…9 Hz), max. 15 m/s
2
(49 ft/s
2
) (9…200 Hz) si-
nusoidal
Max. 1 mm (0.04 in) (5 …
13.2 Hz), max. 7 m/s
2
(23 ft/s
2
) (13.2…100 Hz)
sinusoidal
Max. 0.1 mm (0.004 in)
(10…57 Hz), max. 10 m/s
2
(33 ft/s
2
) (57…150 Hz) si-
nusoidal
Vibration
IEC 60068-2-6:2007,
EN 60068-2-6:2008
With packing max.
100 m/s
2
(330 ft/s
2
),
11 ms
With packing max.
100 m/s
2
(330 ft/s
2
),
11 ms
Not permittedShock
IEC 60068-2-27:2008,
EN 60068-2-27:2009
100 mm (4 in) for weight
over 100 kg (220 lb)
100 mm (4 in) for weight
over 100 kg (220 lb)
Not permittedFree fall
Colors
NCS 1502-Y (RAL 9002 / PMS 420 C)Enclosure
Materials
■ Drive module
For information on the materials used in the drive module, refer to Recycling
instructions and environmental information for ACS880-04, ACS580-04, ACH580-04
and ACQ580-04 (3AXD50000137688 [English]).
■ Package materials for module products
This is a complete list of the package materials. The materials vary depending on the
frame size (packages do not contain all materials listed below).
• Cardboard
1)
• Molded pulp
• Plywood
• Wood
• PP (strapping)
• EPP (foam)
192 Technical data