Motor connection data
Asynchronous AC induction motors, synchronous reluctance motors and
synchronous permanent magnet motors
Motor types
0…
U
1
, 3-phase symmetrical. This is indicated in the type designation label as
typical output voltage level as 3~0…
U
1
.
Voltage (
U
2
)
0…500 Hz. For drives with du/dt filter: 200 HzFrequency
0.01 HzFrequency resolution
See section Electrical ratings (page 177).Current
1 kHz, 2 kHz, 4 kHz, 8 kHz (depends on the parameter settings). See the firm-
ware manual.
Switching frequency
300 m (984 ft) in vector and scalar control modeMaximum recommended
motor cable length
Note: A motor cable that is longer than 100 m (328 ft) may not fulfill the EMC
Directive requirements of Category C3.
Note: Long cables cause a motor voltage decrease which limits the available
motor power. The decrease depends on the motor cable length and character-
istics. Contact ABB for more information. Note that a sine filter (optional) at
the drive output also causes a voltage decrease.
Brake resistor connection data
See chapter Resistor braking (page 241).
DC connection data
Capacitance (mF)
I
DC
(A)ACS580-04-…
U
N
= 400 V
14640505A-4
14714585A-4
14870650A-4
21909725A-4
211033820A-4
211120880A-4
Control panel type
See section Type designation key (page 40).
Control unit data
See chapter Control unit (page 135).
Efficiency
Approximately 98% at nominal power level.
The efficiency is not calculated according to the ecodesign standard IEC 61800-9-2.