EasyManua.ls Logo

ABB ACS580-04 - Leds; Technical Data

ABB ACS580-04
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LEDs
The extension module has one diagnostic LED.
DescriptionColor
The extension module is powered up.Green
Technical data
Into option slot 2 on the drive control unitInstallation
IP20 / UL Type 1Degree of protection
See the drive technical data.Ambient conditions
CardboardPackage
Motor thermistor connection (60…61)
1.5 mm
2
Maximum wire size
DIN 44081 and DIN 44082Supported standards
3.6 kohm ±10%Triggering threshold
1.6 kohm ±10%Recovery threshold
5.0 VPTC terminal voltage
< 1 mAPTC terminal current
< 50 ohm ±10%Short-circuit detection
The PTC input is reinforced/double insulated. If the motor part of the PTC sensor and wiring are rein-
forced/double insulated, voltages on the PTC wiring are within SELV limits.
If the motor PTC circuit is not reinforced/double insulated (ie, it is basic insulated), it is mandatory to
use reinforced/double insulated wiring between the motor PTC and CMOD-02 PTC terminal.
Relay output (62…63)
1.5 mm
2
Maximum wire size
250 V AC / 30 V DC / 5 AMaximum contact rating
1000 VAMaximum breaking capa-
city
External power supply (40…41)
1.5 mm
2
Maximum wire size
24 V AC / V DC ±10% (GND, user potential)Input voltage
25 W, 1.04 A at 24 V DCMaximum power con-
sumption
276 CMOD-02 multifunction extension module (external 24 V AC/DC and isolated PTC interface)

Table of Contents

Other manuals for ABB ACS580-04

Related product manuals