EasyManua.ls Logo

ABB ACS580-04 - Activation Switch; Multiple ACS580-04 Drives, External Power Supply

ABB ACS580-04
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Multiple ACS580-04 drives, external power supply
34
35
36
37
38
OUT1
OUT2
SGND
IN1
IN2
34
35
36
37
38
OUT1
OUT2
SGND
IN1
IN2
STO
K
+ 24 V DC
+ 24 V DC
2
1
STO
2
1
34
35
36
37
38
OUT1
OUT2
SGND
IN1
IN2
STO
2
1
24 V DC
–+
Drive1
Control unit2
Activation switchK
Activation switch
In the wiring diagrams, the activation switch has the designation [K]. This represents
a component such as a manually operated switch, an emergency stop push button
switch, or the contacts of a safety relay or safety PLC.
226 The Safe torque off function

Table of Contents

Other manuals for ABB ACS580-04

Related product manuals