Layout and example connections
1
2
5
4
3
6
2-pin terminal block for relay output42-pin terminal block for external power sup-
ply
3
62
63
CMOD-02
CCU
34
35
X4
36
37
38
OUT1
OUT2
SGND
IN1
IN2
RO PTC C
RO
PTC B
40
41
+
-
24V AC/DC + in
24V AC/DC - in
24 V AC/DC
Common, CRO PTC C62External 24 V (AC/DC) input24 V AC/DC +
in
40
Normally open, NORO PTC B63External 24 V (AC/DC) input24 V AC/DC -
in
41
Grounding screw1Motor thermistor connection5
60
61
PTC IN
PTC IN
One to six PTC thermistors connected in series.
Hole for mounting screw2PTC connectionPTC IN60
Diagnostic LED6Ground (earth) potentialPTC IN61
Mechanical installation
Necessary tools
Screwdriver and a set of suitable bits.
274 CMOD-02 multifunction extension module (external 24 V AC/DC and isolated PTC interface)