SettingParameter
Reverse15.07 RO4 source
1 s15.08 RO4 ON delay
1 s15.09 RO4 OFF delay
Fault and warning messages
Warning A7AB Extension I/O configuration failure.
Technical data
Into an option slot on the drive control unitInstallation
IP20 / UL Type 1Degree of protection
See the drive technical data.Ambient conditions
CardboardPackage
Reley outputs (50…52, 53…55)
1.5 mm
2
Maximum wire size
12 V / 10 mAMinimum contact rating
250 V AC / 30 V DC / 2 AMaximum contact rating
1500 VAMaximum breaking capa-
city
115/230 V inputs (70…78)
1.5 mm
2
Maximum wire size
115 to 230 V AC ±10%Input voltage
2 mAMaximum current leak-
age in digital off state
Isolation areas
HDI
CHDI-01
RO5
RO4
HDI
HDI
1
Plugged to drive SLOT21
Reinforced insulation (IEC 61800-5-1:2007)
Functional insulation (IEC 61800-5-1:2007)