EasyManua.ls Logo

ABB IRB 6640 Foundry Prime - Page 160

ABB IRB 6640 Foundry Prime
496 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Inspecting, mechanical stop pin
Use this procedure to inspect the axis-1 mechanical stop pin.
NoteAction
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
to the robot, before entering the robot working
area.
1
Inspect the axis-1 mechanical stop pin.2
If the mechanical stop pin is bent or damaged, it
must be replaced.
Note
The expected life of gearboxes can be reduced
after collision with the mechanical stop.
160 Product manual - IRB 6640 Foundry Prime
3HAC040586-001 Revision: N
© Copyright 2011-2018 ABB. All rights reserved.
3 Maintenance
3.3.12 Inspecting the axis-1 mechanical stop pin
Continued

Table of Contents