Loading...
NoteAction
DANGER
There is stored energy built up by high
tensioned compression springs inside the
balancing device! When a coil is cut the
released tension creates a spatter of
sparks and flames.
The working area must be free of flam-
mable materials. Position the balancing
device so that the spatter will be directed
away from personnel.
5
Use a cutting torch with a long shaft.Cut the coils of the springs inside the
housing as specified below:
Outer spring: cut at least five coils!
Middle spring: cut at least four coils!
Inner spring: cut at least four coils!
6
Double-check the number of coils cut and
make sure all the tension in the springs
are removed.
7
Product manual - IRB 6640 Foundry Prime 455
3HAC040586-001 Revision: N
© Copyright 2011-2018 ABB. All rights reserved.
6 Decommissioning
6.4 Decommissioning of balancing device
Continued