WARNING
If the pressurized air contains oil, it could result in a brake failure in the motors
and cause the robot arms to fall down, leading to personal injury or physical
damage.
Note
To secure the supply of air pressure, use a pressure sensor.
Air quality for pressurizing of robot
The air must be dry and clean, such as instrument air. The following table describes
the air specifications.
ValueParameter
<+2°C at 6 barDew point
<5 micronsSolid particle size
<1 ppm (1 mg/m
3
)Oil content
>200 L/minAir flow
Pressurizing equipment
ABB recommends a safety valve (if not included) set at 0.4 bar, pressure sensor
set at 0.2-0.3 bar or regulator set for maximum 0.3 bar to be attached on the
pressure side of the air system.
Example of products:
DescriptionEquipment
Festo SDE1-seriesPressure sensor
Festo LRP-seriesPressure regulator
Connect air hose to over pressure limiter unit
Note
ABB recommends the air pressure to be set at maximum 0.3 bar.
Continues on next page