NoteAction
If the LED is:
OFF, the unit is faulty, or it does
not have sufficient input voltage,
or the connection of the connector
X2 is not ok. Proceed with step 5.
Flashing: An internal error has oc-
curred, proceed with step 13.
Check the LINK LED on the Connected
Services Gateway.
4
Use a multimeter and insulating gloves.Measure the input voltage to the Connec-
ted Services Gateway.
5
The input voltage should be 24 V.
Make sure that connector X1 is connected
properly on both ends.
If the input voltage is normal, pro-
ceed with step 6.
If the input voltage is abnormal,
Troubleshooting the main com-
puter on page 416.
Tip
For more details, see Circuit dia-
gram - OmniCore V250XT, rev 04 or later.
Make sure that connector X2 is connected
properly on both ends.
If the connection is OK, proceed
with step 7.
If there is a problem with the con-
nection, repair the connection and
go back to step 3.
Check that the connector X2 is well con-
nected and the network connection prop-
erties are available.
6
If the RF LEDs are:
ON, the Connected Services Gate-
way is connected to network and
works well.
OFF, the Connected Services
Gateway is faulty or the connection
of the connector X3 is not ok. Pro-
ceed with step 8.
Check the indicator RF LEDs on the
Connected Services Gateway.
7
Make sure that connector X3 is connected
properly on both ends.
If the connection is OK, proceed
with step 9.
If there is a problem with the con-
nection, repair the connection and
go back to step 7.
Check that the connector X3 is well con-
nected.
8
If the antenna is not working, repair
the connection or move the an-
tenna to a location with better RF
signal.
If the antenna is ok, proceed with
step 13.
Check that the right type of the antenna
is connected properly.
Tip
Try moving the antenna to different loca-
tions if the RF signal level is low.
9
Verify that the configuration is done cor-
rectly.
On the FlexPendant, check the connec-
tion log in Backup and Restore.
10
Verify that the mobile operator is detected
(for 3G).
Continues on next page
Product manual - OmniCore V250XT Type B 401
3HAC087112-001 Revision: A
© Copyright 2023-2023 ABB. All rights reserved.
7 Troubleshooting
7.3.8 Troubleshooting the 3G Connected Services gateway
Continued