Operation
Manual
1.3
Operating
Environment
Pu
l
l
out
the
fuse
holder
using
a
slotted
head
screwdriver
.
Fuse
holder
Check
(and
replace
if
neces-
sary)
the
power
fuse
and
put
it
back
into
the
fuse
holder
.
Fuse
(T5A
co
mp
l
i
a
n
t
)
Fuse
holder
Spare
fuse
attached
to
the
fuse
holder
.
Figure
1
-2
Replacing
the
Power
Fuse
1-6
27
29
Table of Contents
Default Chapter
13
Table of Contents
13
1 N T R O D U C T I O N
23
Product Description
23
Accessories
24
Standard Accessories List
24
Power Cable Options
25
Operating Environment
26
Environmental Conditions
26
P O W E R Requirements
27
P O W E R Fuse
27
P O W E R Cable
29
Power Cable
29
System Checkout
30
Connecting the Power Supply Cable
30
Screen Display after Self Tests Have Completed
31
Cleaning, Storing and Transporting the Analyzer
33
Cleaning
33
S T O R I N G
34
Transporting
34
Replacing Parts with Limited Life
35
2 P E R at I O N
37
Panel Description
37
F R O N T Panel
37
Front Panel
37
Screen Annotation
37
Unit Key Settings
41
Screen Annotation
46
R E a R Panel
48
Rear Panel
48
B a S I C Operation
50
Operating Menus and Entering Data
50
Displaying Spectrums and Operating the Markers
53
Factory Defaults Screen
54
Calibration Signal Output Screen
54
Measuring Settings Screen
56
Frequency Difference between the Peak Point and a Point 3 Db Levels down
58
Frequency Difference between the Peak Point and a Point 60 Db Levels down
58
Measuring Window and the Display Line
59
Factory Defaults Screen
59
Calibration Signal Output
60
Measuring Settings Screen
60
Activating the Display Line
61
Screen Display Showing the Measuring Window
63
Screen Display after Zoom in
63
Measuring Frequency Using Counter
64
Factory Defaults Screen
64
Calibration Signal Output Screen
65
Measuring Settings Screen
65
Frequency Counter Measurement (Resolution: 1 Khz)
66
Frequency Counter Measurement (Resolution: 10 Hz)
66
Frequency
66
Marker
66
A U T O Tuning
67
Screen Display Prior to Auto Tuning
67
Tracking Operations
69
Signal Tracking Screen
70
Continuous Peak Search Screen
71
UNCAL Messages
72
Measuring Settings Screen
73
Separating Two Signals
75
Setup for Measuring Two Signals Separately
75
Screen Display Prior to Changing the RBW
79
Screen Display after Changing the RBW
80
Screen Display after Changing the VBW
80
Dynamic Range
81
Input Saturation
82
Screen Display Without Saturation
83
Screen Display Showing Saturation
84
Harmonic Distortion
85
Setup for Measuring Harmonic Distortion
85
Screen Display Showing Harmonic Distortion
86
Screen Display Showing Reduced Harmonic Distortion
87
Intermodulation
88
Setup for Measuring Intermodulation
88
Screen Display Showing Intermodulation Distortion
89
Screen Display Without Intermodulation Distortion
90
Calibration
91
Screen Display Showing the Cal Menu
91
Entering User-Definable Antenna Correction Data
92
Editing the Correction Data Table
93
Measurement Examples
94
Measuring the Channel Power
94
Screen Display Showing the User-Definable Correction Data Table
94
Setup for Measuring the Channel Power
95
Setting the Offset Level
96
Setting the Measuring Window
97
Measuring the Channel Power
97
Measuring the Occupied Bandwidth (OBW)
98
Setup for Measuring the Occupied Bandwidth
98
Setting the Detector Mode
99
Measuring Adjacent Channel Leakage Power (ACP)
101
Measurements Using the ACP POINT Method
101
Setup for Measuring the Adjacent Channel Leakage Power
101
Setting the Specified Bandwidth
103
Measurements Using the ACP GRAPH Method
104
Setup for Measuring the Adjacent Channel Leakage Power
104
Measuring the VA Ratio
107
Setup for Measuring the VA Ratio
107
Measuring the Video Carrier Level
109
Measuring the Audio Carrier Level
109
Measuring Window Screen
112
Pass-Fail Judgments
113
Harmonic Distortion Measurements
114
Setup for Measuring the Harmonic Distortion
114
Measuring the Fundamental Wave
115
Measuring the Harmonic Distortion
116
Measurements Using TG (Option 74)
117
Connecting the Unit under Test
119
Other Functions
120
U S I N G Floppy Disks
120
S a V I N G or Recalling Data
124
Display after Data Has Been Saved to a File
126
Screen Display Showing File Protection Enabled
127
Screen Display Showing the Selected File
128
Screen Display Showing Recalled Data
128
Outputting Screen Data
131
Screen Display Showing Floppy Disk as the Specified Destination
131
Setting Date and Time
135
Time/Date Menu
135
Screen Showing the Date Being Set
136
Screen Showing the Hour Being Set
136
M E N U Index
139
Menu Map
144
M E N U Function Descriptions
151
A U T O TUNE Key (Auto Tuning)
151
B W Key (Bandwidth)
152
C a L Key (Calibration)
153
CONFIG Key (Configuration)
154
C O P y Key (Hard Copy)
156
COUNTER Key (Frequency Counter)
157
DISPLAY Key (Line and Window)
158
E M C Key (EMC Measurement)
160
F R E Q Key (Frequency)
162
Hold Mode
163
LEVEL Key (Frequency Level)
164
LOCAL Key (GPIB Remote Control)
166
M E a S Key (Measurement)
167
M K R Key (Marker)
169
PAS/FAIL Key (Pass-Fail Judgment)
174
P K SRCH Key (Peak Search)
175
POWER MEASURE Key (Power Measurement)
176
PRESET Key (Initialization)
178
RECALL Key (Data Readout)
179
REPEAT Key (Continuous Sweep)
180
S AV E Key (Saving Data)
181
S E L F TEST Key (Self Test)
182
SINGLE Key (Single Sweep)
183
S PA N Key (Frequency Span)
184
SWEEP Key (Sweep Time)
185
T G Key (Tracking Generator) (Option 74)
186
TRACE Key (Trace Data)
188
T R I G Key (Trigger)
190
Setting Values
191
S E T Resolution
191
Center Frequency Set Resolution Vs. Frequency Span
191
Frequency Span Set Resolution Vs. Frequency Span
191
S E T Values for RBW, VBW and SWP Time
192
Factory Defaults
193
Defaults Configuration Values
194
4 E M O T E Programing
195
GPIB Remote Programming
196
G P I B Interface Functions
197
Responses to Interface Messages
197
Message Exchange Protocol
199
C O M M a N D Syntax
200
D a T a Formats
200
S T a T U S Bytes
202
Arrangement of the Three Status Registers
203
Details of the Three Status Registers
204
G P I B Command Codes
208
Sweep Mode
210
Sweep Time
210
Peak Search
212
Pass-Fail Judgment
216
Auto Tuning
216
Power Measurement
217
Data Save/Recall (1 of 2)
220
Data Save/Recall (2 of 2)
221
Hard Copy
222
Trace Data
222
Data Input
224
Basic Programming
225
D a T a Output Format (Talker)
227
Trace Data I/O
231
Using the Status Byte
237
R S -232 Remote Control Function
241
G P I B and RS-232 Compatibility
241
Features of RS-232 Remote Control
241
Parameter Setup Window
241
Parameter Setup
241
Interface Connection
242
Connection between the Controller and the Spectrum Analyzer
242
Cable Wiring Diagram
243
D a T a Format
244
Differences between RS-232 and GPIB
245
P a N E L Control
245
R E M O T E Control Usage Examples
245
5 P E C I F I C at I O N S
247
Appendix 1 Error Message
253
Appendix 2 Glossary
257
Dimensional Outline Drawing
264
Alphabetical Index
266
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the ADVANTEST R3131 Series and is the answer not in the manual?
Ask a question
ADVANTEST R3131 Series Specifications
General
Brand
ADVANTEST
Model
R3131 Series
Category
Measuring Instruments
Language
English
Related product manuals
ADVANTEST R3131
261 pages
ADVANTEST R3131A
12 pages
ADVANTEST R3162
588 pages
ADVANTEST R3765G Series
446 pages
ADVANTEST TQ8210
37 pages