R3765/67G Series
Network Analyzer
Operation Manual
FOE-8370681G01
1999
First printing December 1 1999
Applicable models
R3765AG
R3765BG
R3765CG
R3767AG
R3767BG
R3767CG
Cover

Table of Contents

Questions and Answers

  • D
    Diana LunaAug 7, 2025
    What to do if the measured result is incorrect on ADVANTEST Measuring Instruments?
    • D
      Diana GuerreroAug 8, 2025
      If the measured result is incorrect, it might be because the calibration was not performed correctly. Execute the calibration to meet the measurement requirements.
  • R
    Renee ParkerAug 12, 2025
    How to fix ADVANTEST R3765G Measuring Instruments when the power cannot be turned on?
    • B
      Brittany ValenciaAug 12, 2025
      If the power cannot be turned on, consider these potential causes: * The power cable might not be securely inserted. Turn the power switch OFF and reconnect the power cable. * The power fuse might be blown. Replace the power fuse.
  • A
    Amy BurnsAug 16, 2025
    What to do if no trace appears on the screen of ADVANTEST Measuring Instruments?
    • W
      Willie JohnsonAug 16, 2025
      If no trace appears on the screen, check the following: * The BACK LIGHT may be set to OFF. Press the BACK LIGHT button to switch it ON. * The input cable or connector might be loose. Reconnect the input cable or connector.
  • W
    wkellerAug 20, 2025
    What to do if key does not work on ADVANTEST R3765G Measuring Instruments?
    • C
      castillojanetAug 21, 2025
      If a key does not work, it could be because the instrument is in GPIB remote control mode. If a program is being executed, stop it and press the LCL key.
  • R
    Ryan CollinsAug 25, 2025
    Why ADVANTEST R3765G does not sweep?
    • M
      Michael AvilaAug 25, 2025
      If the device does not sweep, the trigger might be set to SINGLE. Set it to CONTINUOUS.
  • M
    moorekathyAug 29, 2025
    What to do if data cannot be recorded (saved) in floppy disk on ADVANTEST R3765G Measuring Instruments?
    • B
      benjaminwangAug 29, 2025
      If data cannot be recorded (saved) on a floppy disk, consider the following: * The floppy disk may not be initialized. Initialize the floppy disk. * The write protect may be enabled. Release the write protect. * The drive may not be set to A:drive. Set it to A:drive.
  • S
    Samuel CarrSep 2, 2025
    What to do if data cannot be read (recalled) from floppy disk on ADVANTEST R3765G Measuring Instruments?
    • J
      Jennifer PerezSep 2, 2025
      If data cannot be read (recalled) from a floppy disk, check these potential causes: * The floppy disk may be defective. Check the operation with another floppy disk. * The drive may not be set to A:drive. Ensure it is set to A:drive.