R3765/67G Series Network Analyzer Operation Manual
7.4 RESPONSE Block
7-24
7.4.7 TRACE Operation
The trace operation is used to execute fundamental arithmetic operation between the measure-
ment data and memory data.
The Setting and the Explanation
Press the [DISPLAY] to call the display menu. (Refer to section A.4.)
Press the {DEFINE TRACE[ ]} to call the trace operation.
Trace operation menu
{DATA/MEM} : Executes the division of measurement data and memory
data, then displays the result as the measurement data.
{DATA-MEM} : Executes the subtraction of measurement data and
memory data, then displays the result as the
measurement data.
{DATA
*
MEM} : Executes the of multiplication of measurement data and
memory data, then displays the result as the
measurement data.
{DATA+MEM} : Executes the addition of measurement data and
memory data, then displays the result as the
measurement data.
{OFF} : Cancels the operation (calculation).