Software 95
4510001 REV B - 220620
“Timing Screw Speed” Field:
Sets the amount of power supplied to the Timing Screw (in Hz), which translates to the
rotation speed of the Timing Screw. A higher value causes the Timing Screw to turn more
quickly, allowing more bottles per minute to be allowed to flow through the LX-150. This is a
“live” field. Select “Set” to accept an entered value.
“Aux Belt” Field:
Sets the amount of power supplied to the Auxiliary Belts / Bottle Holding Devices (in Hz), if
used, which translate to the speed of the Auxiliary Belts / Bottle Holding Devices. A higher
value causes the Auxiliary Belts / Bottle Holding Devices to move faster. The Auxiliary Belts
/ Bottle Holding Devices should visually move at the same speed as the Conveyor Belt, but
this does not mean that they will need the same amount of power. This is a “live” field.
Select “Set” to accept an entered value.