Local alarms signaling
...................................................................................................................................................................................................................................
Introduction
This is the default mode on the 1643 AM or 1643 AMS.
The MDOs behavior in this mode:
MDO-2 is active when one or more local alarms (including possible MDI alarms)
with severity PROMPT are raised
MDO-3 is active when one or more local alarms (including possible MDI alarms)
with severity DEFERRED are raised
MDO-4 is active when one or more local alarms (including possible MDI alarms)
with severity INFO are raised.
Example
This mode is fine for the following application:
Equipment provisioning
...................................................................................................................................................................................................................................
5-12
Alcatel-Lucent - Proprietary
See notice on first page
365-312-807R7.2
Issue 4, May 2007