Provisioning station clock output
...................................................................................................................................................................................................................................
When to use
The purpose of this procedure is to specify the timing source to be used as a reference
for the station clock output signals.
The procedure must be executed when:
A timing reference needs to be provided to external “in station” equipment.
A regenerator loop is needed.
Related information
Related procedures are:
“Provisioning timing sources (p. 7-19)
“Provisioning system timing” (p. 7-29)
“Provisioning output port timing” (p. 7-44)
Parameters used in this procedure can be found at “Parameters for provisioning station
clock output” (p. 7-40).
Before you begin
Before starting this procedure, make sure that:
The Provision Timing Sources procedure is completed
The network timing plan is available
Set priority and lock out
To set the priority or the lockout for a timing source follow this procedure:
...................................................................................................................................................................................................
1
Select Provisioning --> Timing --> Output Timing.
Result: The Provisioned NE Station Clock Output Timing Information window
appears.
...................................................................................................................................................................................................
2
Select a source to edit from the list and click Edit in the Station Clock Output Timing
Sources field
.
Result: The Edit Automatic Selection Criterions for NE STCLK Output Timing
window appears.
...................................................................................................................................................................................................
3
Set Priority or Lock Out Request.
Timing provisioning
...................................................................................................................................................................................................................................
7-36
Alcatel-Lucent - Proprietary
See notice on first page
365-312-807R7.2
Issue 4, May 2007