Provisioning system timing
...................................................................................................................................................................................................................................
When to use
The purpose of Provision System Timing is to lock the network element
synchronization and outgoing timing signals to a timing source with the highest quality
level.
This procedure should be performed in the following cases:
As the second procedure in network element timing provisioning.
If the network element system timing is required to operate in the lock out mode.
Pay attention to the following items:
When used, do not forget to clear the lockout condition after maintenance.
Related information
Related procedures are:
“Provisioning timing sources (p. 7-19)
“Provisioning output port timing” (p. 7-44)
Parameters used in this procedure can be found at .“Parameters for provisioning system
timing” (p. 7-32)
Before you begin
Before starting this procedure, make sure that:
The Provision Timing Sources procedure is completed.
The network element synchronization plan must be available.
Set priority and lock out
To set the priority or the lockout for a timing source follow this procedure:
...................................................................................................................................................................................................
1
Select Provisioning --> Timing --> System Timing.
Result: The Provisioned NE System Timing Information window appears.
...................................................................................................................................................................................................
2
Select a source to edit from the list and click Edit in the System Timing Sources field.
Result: The Edit Automatic Selection Criterions for NE System Timing window
appears.
...................................................................................................................................................................................................
3
Set Priority or Lock Out Request.
Important! A lock out request cannot be made if the priority is disabled.
Timing provisioning
...................................................................................................................................................................................................................................
365-312-807R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
7-29