Create a new ASAP
...................................................................................................................................................................................................................................
When to use
This procedure is used to create new alarm severity assignment profiles (ASAP).
Related information
For related information, please refer to:
“Alarm Severity Assignment Profile” (p. 6-46)
Before you begin
Before performing this task, you must have an overview of the network topology.
1. Log into the ITM
®
CIT, and
2. Connect to the NE.
Required equipment
The following equipment is required to perform this task:
ITM
®
CIT
Procedure
Follow this procedure to create a new ASAP:
...................................................................................................................................................................................................
1
Select Alarms ASAP List.
Result: The Alarm Severity Assignment Profiles List window is displayed.
...................................................................................................................................................................................................
2
Click on Add.
Result: The Create Alarm Severity Assignment Profile window is displayed.
...................................................................................................................................................................................................
3
In the field ASAP Name enter the name of the new ASAP to be created.
Additional information The following provisioning rules apply to the ASAP name:
1. A user cannot add a new ASAP, using names like “default/Default” (in
uppercase or lowercase).
2. The ASAP name is an alphanumeric string of up to 20 characters.
3. The following characters are permitted in an ASAP name:
Upper case letters (A { Z),
Lower case letters (a { z),
Digits (0 { 9),
Hyphens (-).
Alarm management
...................................................................................................................................................................................................................................
365-312-807R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
6-33