Editing PM counter thresholds
...................................................................................................................................................................................................................................
When to Use
The following procedures must be performed when you want to enable performance
monitoring on a termination point, to set the threshold values and the granularity of the
monitored period.
Related Information
The items below list other relevant information to this procedure:
Procedure to set the SDH TP Mode, for the required prior setting of the ports to be
monitored. Refer to “Provision ports” (p. 5-59).
“Concepts” (p. 10-3)
Parameters used in this procedure can be found at “Parameters for configuring PM on
the ITM-CIT” (p. 10-45).
Before you begin
In order to be able to enter values in the various threshold fields, you must:
Enable the Enable Thresholding checkbox
Edit PM counter thresholds
Follow this procedure in order to modify the values of the counter thresholds
...................................................................................................................................................................................................
1
Select Performance -> PM TP Configuration.
Result: The PM Point Filter window is displayed. The ITM-CIT is in PM
Configuration mode.
...................................................................................................................................................................................................
2
Select a filter from the proposed lists, for each enabled field.
Result: The Slot, Port and AU4 fields dynamically get enabled according to the
PM point type selected.
...................................................................................................................................................................................................
3
Select OK to apply the selection.
Result: The Performance Monitoring Point Filter window disappears. The Edit
Performance Monitoring Point window appears.
...................................................................................................................................................................................................
4
Select a binning period tab and verify that the Enable Thresholding checkbox is
marked.