Important! If you selected a LAN point type, the Bidir 24 hr tab is not available
since bidirectional monitoring is not possible. Also, point types MS, RS, ISDN, and
WAN are not available in the bidir 24 hr tab.
...................................................................................................................................................................................................
4
Enable the counters by marking the Enable Counters check box.
Result: The checkbox Enable Counters is enabled.
...................................................................................................................................................................................................
5
Enable thresholding by marking the Enable Thresholding checkbox.
Result: The threshold crossing functionality is enabled. The systems retrieves the
last saved TR and RTR values from the NE and reports it in each parameter field.
If there is no previously saved TR and RTR values (as for a new termination
point), the system will fill in the default threshold values for those parameters (for
thresholds range, minimum/maximum, and default values, see “Concepts” (p. 10-3).
The Enable Thresholding box is not available for bidirectional 24 hr monitoring.
...................................................................................................................................................................................................
6
Set the threshold values (TR and RTR), if defaults are not desired.
For a selected LAN or WAN point type, the only configurable threshold is for
parameter pDe.
...................................................................................................................................................................................................
7
Select OK.
Result: If a RTR is greater than its TR, a message is displayed regarding the wrong
value. The Edit Performance Monitoring Point Filter window disappears. The
Active Performance Monitoring Points window get dynamically updated if they are
opened.
The Performance Monitoring Measurements window gets only updated by clicking
the
Update button.
E ND OF STEPS
...................................................................................................................................................................................................
Performance monitoring
Enabling counter and setting thresholds
....................................................................................................................................................................................................................................