Viewing and editing MDI information
...................................................................................................................................................................................................................................
When to use
The purpose of these steps is to view and edit MDI names.
Related information
The following procedure is related.
• View and Edit MDO Information
Parameters used in this procedure can be found at “Parameters for viewing or editing
MDI information” (p. 5-54).
Before you begin
Before performing this procedure make sure that the:
• The miscellaneous discrete input are physically connected to the NE.
The following precaution should be noted.
• The MDI name can be no longer than 26 characters.
• It is only possible to have four MDIs per network element.
• The user should select names for the Miscellaneous Discrete Inputs that are both
well-chosen and unique.
Procedure
Follow these steps to view and edit MDI names.
...................................................................................................................................................................................................
1
Select Provisioning → Equipment → MDI.
Result: The Provisioned MDI window appears.
...................................................................................................................................................................................................
2
Select an MDI from the list under Id and Name.
Result: The appropriate MDI is selected.
...................................................................................................................................................................................................
3
Click Edit.
Result: The Edit Provisioned MDI window is displayed. The current name of the
selected MDI is displayed on the name line of this window.
...................................................................................................................................................................................................
4
Enter the Name (max. 26 characters).
...................................................................................................................................................................................................
5
Click OK.
Equipment provisioning
...................................................................................................................................................................................................................................
5-52
Alcatel-Lucent - Proprietary
See notice on first page
365-312-807R7.2
Issue 4, May 2007