Archive cleared alarms
...................................................................................................................................................................................................................................
When to use
The procedures of this section can be used when you want the cleared alarms to be
automatically archived in the history log of a chosen path.
Related information
The following items list other relevant information to this procedure:
• There is no related procedure;
• Related concepts are described in the Concepts of Event Management.
Before you begin
The items below gives information on tasks to perform before beginning the procedure:
• No prerequisite must be met in order to view the alarm lists;
• No precaution are needed when performing this procedure.
Archive cleared alarms
...................................................................................................................................................................................................
1
Select Alarms → Current Alarms or select Provisioning → Equipment → Shelf
Display
, right-click on a slot or a unit and select Alarms from the pop-up menu.
Result: The Current Alarms window appears, showing the currently raised alarms
on that NE.
...................................................................................................................................................................................................
2
Mark the Automatic Update checkbox.
...................................................................................................................................................................................................
3
Mark the Logging checkbox
Result: All cleared alarms upon notifications will be logged to a file as defined in
the
Options (File->Options). From the Options dialog, you can specify the path
and filename for the history log file. See Parameters sub-section.
The
Options item is greyed out if Automatic Update is not enabled prior.
...................................................................................................................................................................................................
4
Click Close
Result: The Current Alarms disappears.
E ND OF STEPS
...................................................................................................................................................................................................
Alarm management
...................................................................................................................................................................................................................................
6-22
Alcatel-Lucent - Proprietary
See notice on first page
365-312-807R7.2
Issue 4, May 2007