Modifying an existing ASAP
...................................................................................................................................................................................................................................
When to use
This procedure is used to rename an existing ASAP and/or modify parameter values for
an ASAP. Default ASAPs cannot be renamed, but parameter values can be modified.
Related information
For related information, please refer to:
• “Alarm Severity Assignment Profile” (p. 6-46)
Before you begin
Before performing this task, you must have an overview of the network topology.
1. Log into the ITM
®
CIT, and
2. Connect to the NE.
Required equipment
The following equipment is required to perform this task:
• ITM
®
CIT
Procedure
Follow this procedure to rename and/or modify parameter values for an ASAP:
...................................................................................................................................................................................................
1
Select Alarms → ASAP List.
Result: The Alarm Severity Assignment Profiles List window is displayed.
...................................................................................................................................................................................................
2
Select the ASAP to be modified in the ASAP List, then click on Details.
Result: The Alarm Severity Assignment Profile Information window is displayed
for the selected ASAP.
...................................................................................................................................................................................................
3
Click on Edit to modify the severity and the reporting state.
Result: The Edit Alarm Severity Assignment Profile window is displayed.
Note: The user can select any alarm to modify and only the selected alarms will be
displayed in the edit window.
...................................................................................................................................................................................................
4
In the field ASAP Name change the name of the ASAP if you want.
Alarm management
...................................................................................................................................................................................................................................
365-312-807R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
6-35