Editing remote NEs in the configured nodes list
...................................................................................................................................................................................................................................
When to use
Use this procedure to edit existing accessible remote network elements in the
configured nodes list. By selecting the node edited in the configured nodes list a
remote login can be established.
Related information
Remote login by using the Configured Nodes list.
Refer to “Concepts” (p. 4-3).
Before you begin
Pay attention to the following:
• When an already specified NSAP is used an error message will be displayed, and
upon the user selecting OK, then will be prompted to re-enter the NSAP value.
• when an incorrect NSAP is specified for example if the characters are not
hexadecimal characters an error message will be displayed, and upon the user
selecting OK, then will be prompted to re-enter the NSAP value.
Procedure
Follow this procedure to add remote logins to the configured nodes list:
...................................................................................................................................................................................................
1
Login to the network element to which the ITM-CIT is physically connected.
Result: A connection is established.
...................................................................................................................................................................................................
2
Select File —> NE Login –> Login.
Result: The NE login window appears.
...................................................................................................................................................................................................
3
Click Edit.
Result: The Edit Accessible Network Element window appears.
...................................................................................................................................................................................................
4
Fill in the fields that need to be modified.
Result: The parameters needed to establish a remote login are changed.
...................................................................................................................................................................................................
5
Click OK.
Management communication setup
...................................................................................................................................................................................................................................
365-312-807R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
4-49