Displaying PM data
...................................................................................................................................................................................................................................
When to use
The following procedures are performed to:
Display details of any termination point settings
Display PM and LAN performance data.
Related information
The items below list other relevant information to this procedure:
Procedure to set the SDH TP Mode, for the required prior setting of the ports to be
monitored. Refer to “Provision ports” (p. 5-59).
“Concepts” (p. 10-3)
Parameters used in this procedure can be found at “Parameters for displaying PM
data” (p. 10-52).
Before you begin
The items below gives information on tasks to perform before beginning the procedure:
A prerequisite for this procedure is to set the port mode to monitored for the TP.
See Related Information below.
The proper LAN card must be installed in TS2 in order to be able to make
performance LAN measurements.
Viewing TP settings & PM measurements
Follow this procedure in order to view the active measurement point settings of the
NE.
...................................................................................................................................................................................................
1
Select Performance -> PM Current Measurements.
Result: The Performance Monitoring Point Filter window is displayed. The
ITM-CIT is in measurement mode.
...................................................................................................................................................................................................
2
Select a PM Point Type Slot and its Port, and any additional SDH level “Filter”
(p. 10-52) (if applicable). And select
OK to apply the selection.
Result: The Active Performance Monitoring Points window appears.
...................................................................................................................................................................................................
3
Select a Performance Monitoring point from the list of provisioned termination points
and Click
Measurements...
Result: The Performance Monitoring Measurements window appears.
...................................................................................................................................................................................................
4
Select a binning period tab and click Update.