Result: The network element name and location appear, respectively, in the fields
NE Name and NE Location.
...................................................................................................................................................................................................
3
Click Next.
Result: The window Node Creation - Provisioned Slots appears.
...................................................................................................................................................................................................
4
Complete the procedure “Provision Slots”.
Important! For the 1643 AM or 1643 AMS, the only slot which may be user
assigned is TS2.
Result: The slots of the NE are properly assigned.
...................................................................................................................................................................................................
5
Complete the procedure “Confirm the MIB” (p. 5-24).
Result: The MIB is now confirmed, and after reestablishing the connection
between the NE and the ITM-CIT, the MIB status in the window Node Details
should be Filled.
...................................................................................................................................................................................................
6
Complete the procedure “Confirm or Update the MIB”.
Result: The MIB is now confirmed, and after reestablishing the connection
between the NE and the ITM CIT, the MIB status in the window Node Details
should be Filled.
E ND OF STEPS
...................................................................................................................................................................................................
Equipment provisioning
Creating a node
....................................................................................................................................................................................................................................
365-312-807R7.2
Issue 4, May 2007
Alcatel-Lucent - Proprietary
See notice on first page
5-17