Slot State Description
Auto Automatically assigns the unit to the slot once the NE establishes
the presence of a unit of the correct type. Until this time, the slot
acts as unassigned.
Main unit
The unit provisioned or to be provisioned in the selected slot.
Upper/lower interface
The interfaces directly associated with the displayed Main Unit.
MIB state
The status of the MIB is indicated. The possible values are given in the table below.
MIB State Description
Empty An empty system controller (SC) has been inserted or the MIB
was cleared after starting an automatic MIB download by the
management system. If the MIB State is empty, the management
system can proceed with the MIB download.
Filled The NE possesses a valid MIB, which has been confirmed.
Filled Unknown The NE has a MIB, however, it is of unknown validity. This can
occur, for instance, if one SC is replaced by another SC having a
MIB.
Filled Not
Confirmed
The NE has a MIB, however, it has not yet been confirmed by
the ITM-CIT or ITM-SC. The procedure “Confirm or Update
MIB” gives the steps necessary to confirm the MIB. Once
confirmed the state will become Filled.