Category
Filters the alarms based on the logical location where the alarms occurred, for example
Equipment filter displays an overview of alarms triggered by a unit failure or a laser
fault conditions. The Transmission filter displays the alarms that are triggered by faults
which are detected in the transmission signal. Processing filter displays alarms
triggered by inconsistencies during the processing of provisioned data. Environment
filter displays alarms, triggered by malfunctions in external equipment which is
supervised by the system. Management , filter displays alarms triggered by
malfunctions in the communication between the Management System and the Network
Element.
Class
For a given class, the classes group a number of alarms generated by an object which
can be the node, a shelf, a slot, a termination point, etc.
Description
The Description field shows the full description of the selected alarm.
Details
The Details... button displays the details of the selected alarm. Only one alarm can
be selected at a time. The button is only selectable when an alarm has been selected
from the list.
Filter
The Filter... button opens the Alarm List Filter Configuration window. In this
window you can change the filter criteria.
Filtering
This check box activates or inactivates the alarm filtering functionality. The alarm
filtering is based on the current alarm filters. Whenever the check box is unmarked
(inactivated), no filtering occurs.
Global reported
The of all alarm instances in the network element. The default sorting order is Yes, No
and <empty>.
Global severity
Settings regarding the urgency of an alarm and which is applicable to all instances of
the same kind in the network element. The default sorting order is Prompt, Deferred,
and Info.
Alarm management
Parameters for identifying the alarms
....................................................................................................................................................................................................................................
6-24
Alcatel-Lucent - Proprietary
See notice on first page
365-312-807R7.2