Creating cross connections without protection
...................................................................................................................................................................................................................................
When to use
When a new traffic plan is implemented or the existing traffic plan is changed.
Related information
The following procedures are used for test and maintenance of the provisioned path.
These procedures are described in Chapter 9, “Traffic maintenance”.
port provisioning.
provisioning termination points
path trace provisioning
for theoretical information see section Traffic Maintenance Concepts.
Before you begin
To make a cross-connection first determine the following
What is the capacity of the cross-connection? VC-12, VC-3 or VC-4
Will the cross connection be used as a loopback for maintenance purposes
Does the cross connection require SNC protection or is it unprotected (Standard)
Between which termination points (TP) is the cross connection made
Before adding a cross connection and, if desired its protection, be sure to have
information regarding the design of the transmission path
Before deleting a cross connection or part of a cross connection be sure to know
whether the cross connection to be removed still carries traffic? If yes this traffic
will be lost after removing the cross-connection
Deleting or changing a cross-connection is traffic affecting if the current existing
cross-connection is carrying traffic.
Procedure
Use the following procedure to add a cross-connection in the 1643 AM or 1643 AMS
network element.
...................................................................................................................................................................................................
1
Select Provisioning -> Transport -> Cross Connection.
Result: The Cross Connection Filter window appears.
...................................................................................................................................................................................................
2
Select the Cross Connection Type, Capacity, Directionality, TP, Slot, Port, and the AU4
number in the Cross Connection Filter window and select
OK.
Traffic provisioning
...................................................................................................................................................................................................................................
8-148
Alcatel-Lucent - Proprietary
See notice on first page
365-312-807R7.2