Editing MSP protection
...................................................................................................................................................................................................................................
When to use
MSP protection should be established when the transmission plan calls for a protection
of a particular point to point connection.
Related information
Related procedures are:
Slot provisioning.
Port provisioning.
Before you begin
Related prerequisites and precautions are:
A protected switch is always traffic affecting.
If the physical timing reference of the units to be MSP protected are assigned to a
single logical timing references then these units are no longer available for MSP
protection.
If a port loopback is set on a port, then this port is not available for MSP
protection
MSP pair must be present physically set up on the Near End and Far End Network
Elements. In other words, a MSP unit available and fiber pairs connected on both
Network Elements.
Procedure
...................................................................................................................................................................................................
1
Select Protection -> Transmission -> MSP.
Result: The Provisioned NE MSP Information window is displayed.
...................................................................................................................................................................................................
2
Make a selection and click Details.
Result: The Details MSP window is displayed.
...................................................................................................................................................................................................
3
View the information. To change the information click Edit (for non-revertive MSP
greyed out).
Result: The Edit MSP window is displayed.
...................................................................................................................................................................................................
4
Make a selection for the WtR Time with usage of the above parameter information and
click
OK.
Traffic provisioning
...................................................................................................................................................................................................................................