Suspect flag
A marker for the data of the 15 minutes and 24 hours bins which is tagged on during
specific situations such as:
the current bins are reset by the ITM-CIT
the performance monitoring is started and stopped
the SES threshold is modified
the time clock changes more than 5 seconds
the stored data is incomplete or invalid because for example the unit is active but
not operational
Termination point
Final destination where an incoming signal is terminated.
TU3 (k00)
A filter that can be applied to identify the TU3 number amongst the possible 3 within
the VC4. The letter “K” stands for KLM number and the last two digits are for the
TU3 number. TU3 is identified by KLM number 100, 200 or 300.
TU12 (KLM)
A filter that can be applied to identify the TU12 number amongst the possible 63
within the VC4 monitored at a given port. The TU12 is identified by giving its KLM
number. An example is 364 where the first digit corresponds to the TUG-3 number
(1..3), the second digit to the TUG-2 number (1..7) and the last digit to the TU-12
number (1..3).
Thresholding (15* or 24*)
Displays the activation state of the thresholding for the corresponding point and the
Unidirectional 15 minutes counter. If disabled, the value of the state is displayed as
“-”.
UAP
Near End unavailable binning period log. The UAP starts at the beginning of 10
consecutive seconds stretch of SES. It stops at the first second of a 10 seconds of more
duration in which there is no longer any SES occurring
Unidirectional 15 minutes
Displays if the displayed PM point Id has an active uni-directional 15 minutes
measurement point.
Unidirectional 24 hours
Displays if the displayed PM Point Id has an active unidirectional 24 hours
measurement point.
Performance monitoring
Parameters for displaying PM data
....................................................................................................................................................................................................................................
10-54