Login to a Network Element
...................................................................................................................................................................................................................................
When to use
To configure the NE
Related information
No related information is available.
Before you begin
Before starting the ITM-CIT application and login in to a NE make sure that:
• the PC is connected to the network element (NE)
• the PC is rebooted at least once after installation.
Procedure
Follow these steps to login to a network element:
...................................................................................................................................................................................................
1
Start the ITM-CIT application.
Result: The main ITM-CIT window appears
...................................................................................................................................................................................................
2
Select File -> NE Login -> Login in the main menu.
Result: The NE Login window appears.
...................................................................................................................................................................................................
3
Select the correct COM port.Usually this is COM1.
...................................................................................................................................................................................................
4
Select Edit to set the correct baudrate.
The baudrate to be used is 115k.
AM1 (plus), TM1 do operate on a baudrate of 115k, the ADM16/1 family, and the
1643 AM is working with 114k.
...................................................................................................................................................................................................
5
Select Login.
Result: The Password Required window appears.
...................................................................................................................................................................................................
6
Select the user role from the capability field.
Getting Started
...................................................................................................................................................................................................................................
2-16
Alcatel-Lucent - Proprietary
See notice on first page
365-312-807R7.2
Issue 4, May 2007