Filter Policies
Router Configuration Guide 645
Description This command monitors the counters associated with the specified entry of the specified IP filter
policy.
Parameters filter-id — The IPv4 filter policy ID. Values can be expressed in different formats. The following
only shows decimal integer format values.
Values 1 to 65535
entry entry-id — Specifies the filter policy entry to monitor, as a decimal integer. .
Values 1 to 65535
interval secondsConfigures the interval for each display in seconds.
Default 10 seconds
Values 3 to 60
repeat repeat — Configures how many times the command is repeated.
Default 10
Values 1 to 999
absolute — When the absolute keyword is specified, the raw statistics are displayed, without
processing. No calculations are performed on the delta or rate statistics.
rate — When the rate keyword is specified, the rate-per-second for each statistic is displayed
instead of the delta.
Default absolute
ipv6
Syntax ipv6 ipv6-filter-id entry entry-id [interval seconds] [repeat repeat] [absolute | rate]
Context monitor>filter
Description This command monitors the counters associated with the IPv6 filter policy.
Parameters ipv6-filter-id — The IPv6 filter policy ID. Values can be expressed in different formats. The
following only shows decimal integer format values.
Values 1 to 65535
entry entry-id — Specifies the filter policy entry to monitor, as a decimal integer. .
Values 1 to 65535
interval secondsConfigures the interval for each display in seconds.
Default 10 seconds
Values 3 to 60