136 Rockwell Automation Publication 1789-UM002K-EN-P - January 2015
Chapter 7 Develop External Routines
Debug External Routines
You can debug external routines by setting up a debug session.
Set Up the Debug Session
If you built your DLL with Program Database Symbolic Information (PDB), you
must copy the PDB file into the directory where the External Routine DLL is
copied during a download to the controller. This file is not copied as a part of the
normal download to the SoftLogix controller.
For example, if you have a controller in slot 3 that is using an External Routine
DLL called InlineExample.dll, copy InlineExample.pdb to:
C:\Program Files\Rockwell Automation\SoftLogix 5800\data\slot03.
The location 1C:\Program Files\Rockwell Automation\SoftLogix 5800’ is
where the SoftLogix controller is installed. The location ‘\data\slot03’ is where
data related to a particular instance of the controller resides. The slot directory is
created as needed when a controller is inserted into the SoftLogix Chassis
Monitor.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley SoftLogix 5800 and is the answer not in the manual?

Allen-Bradley SoftLogix 5800 Specifications

General IconGeneral
BrandAllen-Bradley
ModelSoftLogix 5800
CategoryController
LanguageEnglish

Related product manuals