9-29
9.17 CSAV [Condition Save]
9.15 CPY [Copy]
Function
Copies the screen to the internal printer.
When transfer to the printer is complete, bit 2 (transfer end bit) of the extended
event status register (ESR2) is set to 1.
Execute a CPY command with the printer set Int state.
Header Program Query Response
CPY CPY None None
9.16 CRCL [Condition Recall]
Function
Recalls the condition of the internal backup RAM as the current condition.
Header Program Query Response
CRCL CRCL n None None
Value of n
n is the number of the memory whose condition is to be recalled. Input an integer
between 0 and 5.
9.17 CSAV [Condition Save]
Function
Saves the current condition in the internal backup RAM.
Header Program Query Response
CSAV CSAV n None None
Value of n
n is the number of the memory, 1 to 5, into which the current condition is to be
saved.