E-1
Appendix E
Appendix
This appendix summarizes compatibility between MS9710C spectrum analyzer device messages and MV02
(MS9703A) spectrum analyzer device messages.
MV02 device messages marked with
can be used on the MS9710C.
MV02 device messages marked with × cannot be used on the MS9710C. However, since their functions are similar
to those of the MS9710C, they are given just for reference purpose.
Device Message Compatibility Table
Function
Compatibility
MS9710C device message
Command
Data
request
Data
request
Response
Command
Response
Remarks
MV02 device message
Wave length
Center
CNT λ
λ=xxxx.xx
CNT λ
λ=x.xxxx (µm)
Span SPN λ
λ=xxxx.x
SPN ∆λ
∆λ=0,2 to 1000
(1, 2, or 5 steps)
1200
Stop STO λ
λ=xxxx.x
STO ∆λ
∆λ=0,2 to 1000
(1, 2, or 5 steps)
1200
Start STA λ
λ=xxxx.x
CNT?
SPN?
STO?
STA?
CNT?
SPN?
STO?
STA?
λ
λ=xxxx.xx
λ
λ=xxxx.x
λ
λ=xxxx.x
λ
λ=xxxx.x
λ:
Wavelength
λ:
Wavelength
(nm)
λ:
Wavelength
(nm)
λ:
Wavelength
STA λ
λ=x.xxxx (µm)
λ
∆λ
λ
λ
Unit is different.
Wavelength to
be added to
start wavelength
LOG l
l=xx.x
LOG n
n=0.2 to 10
(1, 2, or 5 steps)
10F
LOG?
LOG?l
l=xx.x
Unit: db/div
0.1 to 10.0
n
Except 10F
RLV L
l=±xx.x
RLV l
A, B, A&B;l=+20 to -90
A-B, B-A,
normalize
;l=+40 to -40
RLV?
RLV?l
l=±xx.x
A, B, A&B;
l=+30 to –90
A-B, B-A,
normalize
l=+100 to –100
l
RES n
n: Shown
on righ
t
RES n
n=0.1,0.2,0.5,1,2,5
RES?
RES?
n
n=
0.07,0.1,
0.2,0.5,1
n: Resolution
(nm)
n
Except n = 2, 5
SMT n
n: Shown
on right
SMT n
SMT?
SMT?
AUT?
AUT?
SSI SSI
SRT SRT
SST SST
AUT
SPC SPC
AUT
n
n=3,5,7,9,11,
OFF
n: Number
of points
n
n
AVT n
n=2 to 1000
OFF
AVT n
n=1 to 1000
AVT?
AVT?
n
n=2 to 1000,
OFF
n
n = 0: Measurement
complete
n = 1: During
measurement
n
n = 0: Measurement
complete
n = 1: During
measurement
n: Count
n
Corresponds to
n = 2 to 1000
Corresponds
to 3 to 11
LLV l
LLV l
PKL
PKL
LLV?
LLV?l
l: Level
1pW to 1W
1 to 200 %
l
Unit is different.
PeakCenter PKC PKC
Level Scale
LVS? LVS?
Log (/div)
S
S = LOG
LIN
Log scale
Linear scale
s
s = LOG
LIN
Ref Level
Linear
PeakLevel
Resolution
Point Avg
Smooth
Sweep
Single
Repeat
Stop
Auto Measure
Measure Mode
MOD?
MOD?
n
n = 0: Spectrum
not measured
n = 1: Spectrum
single sweep
n = 2: Spectrum
repeat sweep
n = 3: Power
monitor
Spectrum
Go to spectrum measurement
Appendix E MS9710C and MV02 (MS9703A) Com-
mand Compatibility Table

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Anritsu MS9710C and is the answer not in the manual?

Anritsu MS9710C Specifications

General IconGeneral
BrandAnritsu
ModelMS9710C
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals