Appendix
C-2
Controller
Function
PACKET V PC9801 IBM-PC HP9000 series
Trigger the
specified device
TRG @ device-number WBYTE &H3F,
listener-address,
secondary-address,&08;
CALL
IBTRG( )
TRIGGER
Device selector
Initialize device
DCL @select-code (all
devices with
corresponding to
specified select code)
DCL @ device-number
(only specified devices)
WBYTE
&H3F,&H14;WBYTE
&H3F,
listener-address,
secondary-address,
H04;
CLEAR
Device selector
(select-code)
CLEAR
Device selector
(select-code +
primary address)
Disable
switching of
device from
remote to local
LLO @ select-code WBYTE &H3F,&H11; LOCAL
LOCKOUT
Transfer control
right to specified
device
RCT @ device-number
WBYTE talker-
address,&H09
CALL
IBPCT( )
PASS CONTROL
Issue service
request
SRQ @ select-code ISET SRQ CALL
IBRSV( )
REQUEST
select-code
Perform serial
polling
STATUS @ device-
number
POLL CALL
IBRSP( )
SPOLL
(Device selector)
(Function)
Set terminator
code
TERM IS CMD DELIM CALL
IBEOS( )
CALL
IBEOT( )
Set limits value
for timeout check
CMD TIMEOUT CALL
IBTOM( )
.