Section 4 Initial Setting
4-14.
Items not changes at power-on
(1) Address
(2) Associated calibration data
(3) Data and states that change with the responses to the following common
query commands
IDN? (
Section 7)
OPT? (
Section 7)
PSC? (Not supported by the MS9710C)
PUD? (Not supported by the MS9710C)
RDT? (Not supported by the MS9710C)
Items related to power-on status clear (PSC) flag
When the PSC flag is false, the service request enable register ( Sec-
tion 8.3), standard event status enable register (
Section 8.4), and paral-
lel poll enable register are not affected.
When the PSC flag is true or the PSC command has not been executed, the
above registers are not cleared.
( The PSC command is not supported by the MS9710C)
Items that change at power-on
(1) Current device function test
(2) Status information
(3) SAV/RCLregister (Not supported by the MS9710C)
(4) Macro definition made with a DDT command
(Not supported by the MS9710C)
(5) Macro definition made with a DMC command
(Not supported by the MS9710C)
(6) Macro definition made with an EMC command
(Not supported by the MS9710C)
(7) Address received with a PCB command (Not supported by the MS9710C)