EasyManuals Logo

AVALEX TECHNOLOGIES AVR8414 User Manual

AVALEX TECHNOLOGIES AVR8414
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
Page | 77 of 105
AVR8414 Operation Manual Rev O
Table 8 Messages by Event
ID
Event
On-Screen Display
(OSD) Message
Front Panel Message
29
An attempt to export a log has failed.
<EXPORT TYPE>
EXPORT FAIL TARGET:
<STORAGE DEVICE>
<STORAGE DEVICE>
EXPORT FAIL
30
A log or DVR settings was successfully
exported.
<EXPORT TYPE>
EXPORT DONE
<EXPORT TYPE>
EXPORT DONE
31
The software update failed because there
was not enough room.
SW UPDATE FAILED.
ERROR: REPO TO FULL
SW UPDATE FAILED
32
The software update failed because no
software package was found on the
selected storage device.
NO SW UPDATE ON
<STORAGE DEVICE>
NO SW UPDATE ON
<STORAGE DEVICE>
33
The software update failed because
software package could not be copied.
SW UPDATE FAILED.
ERROR: GET PACKAGE
TO REPO
SW UPDATE FAILED
34
The software update failed because
software package md5 checksum does not
match the calculated md5 checksum.
SW UPDATE FAILED.
ERROR: md5cmd
checksum failed
SW UPDATE FAILED
35
The software update failed because
software package could not be unpacked.
SW UPDATE FAILED.
ERROR: UNPACK
SW UPDATE FAILED
36
The CODEC capture needs to be
reconfigured to allow pass-through of
selected channel. Capture cannot be
reconfigured if the CODEC is already in use
for recording or reach-back or playback.
CAN'T SET PASSTHRU!
STOP REC<#> AND TRY
AGAIN
CAN'T SET PASSTHRU
37
Configuration import failed because the
new configuration could not be unpacked.
LOAD FAILED. ERROR:
UNPACK
LOAD FAILED
38
Configuration import failed because the
new configuration file does not exists.
LOAD FAILED. ERROR:
UNPACK NO FILE
LOAD FAILED
39
Configuration import failed because the
new configuration file is empty (size is
zero).
LOAD FAILED. ERROR:
UNPACK EMPTY
LOAD FAILED
40
Configuration import failed because the
configuration file copy to system failed.
LOAD FAILED. ERROR:
COPY
LOAD FAILED
41
Configuration import failed because play or
record is active.
LOAD FAILED. ERROR:
CANNOT UPDATE
CONFIG WHILE PLAY
OR RECORD IS ACTIVE
LOAD FAILED
42
Configuration import failed because reach-
back is active.
LOAD FAILED. ERROR:
CANNOT UPDATE
CONFIG WHILE PLAY
OR REACHBACK IS
ACTIVE
LOAD FAILED
43
Configuration import failed because the
configuration source storage device was
not found.
LOAD FAILED. ERROR:
<STORAGE DEVICE>
NOT FOUND
LOAD FAILED

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AVALEX TECHNOLOGIES AVR8414 and is the answer not in the manual?

AVALEX TECHNOLOGIES AVR8414 Specifications

General IconGeneral
BrandAVALEX TECHNOLOGIES
ModelAVR8414
CategoryMeasuring Instruments
LanguageEnglish