Configuration Mode (ConF)
Incompatible Functions
The following function will be inaccess ible or deactivated after an Autom atic res tart.
This is only poss ible for control type if
[2/3 wire control]
(tCC) is set to
[2 wire]
(2C) and if
[2 wire type]
(
tCt
) is s et to
[Level]
(
LEL
) or
[Fwd p
r
io
rity]
(
PFO
). See
[2/3 wi
re
control]
(
tC
C
) page 85.
The
[1.2 MONITORING]
(MOn-) m enu page 47 can be used to dis play the functions ass igned to each input
in order to check their com patibility.
When a function is as signed, a appears on the graphic display term inal, as illustrated in the exam ple below:
RAMP
STOP CONFIGURATION
AUTO DC INJECTION
If you attem pt to ass ign a function that is incom patible with another function that has already been as signed,
an alarm m es sage will appear:
•
With the graphic dis play term inal:
The f unction can't be assigned
because an incompatible
f unction is already selected. See
programming book.
ENT or ESC to continue
•
With the integrated dis play term inal and the rem ote display term inal:
COMP flas hes until ENT or ESC is press ed.
When you as s ign a logic input, an analog input, a reference channel or a bit to a function, pres sing the HELP
key will dis play the functions that may already have been activated by this input, bit or channel.
When a logic input, an analog input, a reference channel or a bit that has already been ass igned is as signed
to another function, the following screens appear:
•
With the graphic dis play term inal:
If the acces s level perm its this new as signment, pres sing ENT confirm s the as signment.
If the acces s level does not perm it this new as signment, pres s ing ENT results in the following dis play:
f unctions, or select
"Adv anced" access level
•
With the integrated dis play term inal:
The code for the firs t function, which is already as signed, is displayed flas hing.
If the acces s level perm its this new as signment, pres sing ENT confirm s the as signment.
If the acces s level does not perm it this new as signment, pres s ing ENT has no effect, and the m es s age
continues to flas h. It is only poss ible to exit by press ing ESC.
Parameters described in this page can be accessed by:
DRI- > CONF > FULL > FUN- > REF-