Configuration Mode (ConF)
215
Torque
limitation via
parameter
Low est value
taken into account
[LI]
LI
[No]
Limitation
value
na
log
l
i
m
i
t
.
t
.
[Yes]
[AI]
[LI]
[No]
LI
TORQUE LIMITATION
There are two types of torque lim itation:
•
With a value that is fixed by a param eter
•
With a value that is set by an analog input (AI or pulse)
If both types are enabled, the lowes t value is taken into account. The two types of lim itation can be configured
or s witched rem otely us ing a logic input or via the com m unication bus.
[Torqu
e
limit. activ.]
(
tL
A
)
[M otoring torque
lim]
(
tL
IM
)
[Gen. torque lim]
(
t
LIG
)
[Torque ref. assign.]
(
tAA
)
Parameters described in this page can be accessed by:
DRI- > CONF > FULL > FUN- > TOL-
[AI.]
(